Mwrf 1103 42rteaser 0

Tester Reads Phase Noise To 26 GHz

Dec. 31, 2013
This versatile phase-noise test set provides results for carriers through 26 GHz across a wide range of offset frequencies.
Download this article in .PDF format
This file type includes high resolution graphics and schematics when applicable.

Phase noise can cripple advanced modulation formats in modern communications systems, which is why it should be carefully characterized for the high-frequency signal sources used in those systems. Fortunately, the recently introduced model 7300 phase-noise test system from Berkeley Nucleonics can perform a variety of noise and other measurements on RF/microwave signal sources—such as oscillators and frequency synthesizers—from 5 MHz to 26 GHz while maintaining a low noise floor for enhanced accuracy.

The model 7300 phase-noise test system (see figure) is a compact, single-box solution that employs proven cross-correlation procedures for reliable measurements. Such techniques are commonly used to search for short events among waveforms of longer duration. Cross-correlation measurements compare two or more waveforms that are delayed relative to one another, and the approach can be used for pulsed, modulated, and continuous-wave (CW) signals.

This single-box phase-noise test solution enables measurements across a wide range of offsets for carriers to 26 GHz.

The measurements are well suited to comparing delayed versions of signals for different types of noise. These include amplitude-modulation (AM) noise or phase noise using the appropriate detection circuitry, such as an AM detector or a phase detector. The 7300 series phase-noise test systems include self-calibration routines and automated frequency-acquisition techniques to simplify and speed measurements.

The model 7300 phase-noise tester includes an internal frequency reference, but can also operate with an external frequency reference (from 5 MHz to 6 GHz). It can work with internal references from 2 MHz to 26 GHz with spurious levels of typically -75 dBc, and can track a device under test (DUT) over a range of ±100 ppm. It can work with external references from 5 MHz to 6 GHz at power levels from +8 to +18 dBm and tuning voltages from 0 to +20 VDC.

The phase-noise tester tackles carriers from 5 MHz to 26 GHz and measures phase-noise levels at offsets of 0.1 Hz to 1 MHz from those carriers. It works for an input power range of -10 to +20 dBm for carriers to less than 6 GHz; for 0 to +20 dBm for carriers to less than 20 GHz; and for +3 to +20 dBm for carriers from 20.0 to 26.5 GHz. The instrument itself exhibits a residual phase-noise floor of-140 dBc/Hz offset 1 Hz from the carrier; -150 dBc/Hz offset 10 Hz from the carrier; -160 dBc/Hz offset 100 Hz from the carrier; -175 dBc/Hz offset 1 kHz from the carrier; -180 dBc/Hz offset 10 kHz from the carrier; and -180 dBc/Hz offset 1 MHz from the carrier.

Its specified phase-noise measurement accuracy is ±4 dB for offsets less than 10 Hz; ±3 dB for offsets less than 1 kHz; and ±2 dB for offsets greater than 1 kHz. The test time is a function of the number of measurement points, with typical measurement times of 0.2 s for 600 points at offsets from 1 kHz to 1 MHz; 0.5 s for 800 points at offsets from 100 Hz to 1 MHz; 2.5 s for 1000 points at offsets from 1 kHz to 1 MHz; and 12 s for 1200 points at offsets from 1 Hz to 1 MHz.

The phase-noise tester provides numerous input and output connectors for signals and data, including SMA female input signal connectors, rear-panel connectors for DC power (2.5 A at 6 V), a Universal-Serial-Bus (USB 2.0) data connector, an RJ-45 local-area-network (LAN) connector (which supports an Ethernet 100BaseT LAN interface), and various power and baseband connectors. It also provides direct access to its internal Fast Fourier Transform (FFT) analyzer.

The phase-noise tester is also available with an optional GPIB connector for use in automated-test-equipment (ATE) applications, and can be programmed via SCPI Version 1999.0 control language. It weighs 9 lbs (4 kg) and can be used over an operating temperature range of 0 to +45°C. 

Berkeley Nucleonics, 2955 Kemer Blvd., San Rafael, CA 94901; (415) 453-9955, FAX: (415) 453-9956.

Download this article in .PDF format
This file type includes high resolution graphics and schematics when applicable.

Sponsored Recommendations

UHF to mmWave Cavity Filter Solutions

April 12, 2024
Cavity filters achieve much higher Q, steeper rejection skirts, and higher power handling than other filter technologies, such as ceramic resonator filters, and are utilized where...

Wideband MMIC Variable Gain Amplifier

April 12, 2024
The PVGA-273+ low noise, variable gain MMIC amplifier features an NF of 2.6 dB, 13.9 dB gain, +15 dBm P1dB, and +29 dBm OIP3. This VGA affords a gain control range of 30 dB with...

Fast-Switching GaAs Switches Are a High-Performance, Low-Cost Alternative to SOI

April 12, 2024
While many MMIC switch designs have gravitated toward Silicon-on-Insulator (SOI) technology due to its ability to achieve fast switching, high power handling and wide bandwidths...

Request a free Micro 3D Printed sample part

April 11, 2024
The best way to understand the part quality we can achieve is by seeing it first-hand. Request a free 3D printed high-precision sample part.