Leverage RF Power Meters For EM Compatibility Testing

March 4, 2014
Power meters could enhance testing for electromagnetic compatibility and aid engineers in designing devices resistant to EMI. As a replacement for diode detectors, power meters could improve the quality of EMI/EMC test.
Download this article in .PDF format
This file type includes high resolution graphics and schematics when applicable.

As the complexity of modern telecommunications equipment increases, related standards and methods of testing them do as well. Recent changes to electromagnetic-interference (EMI) and electromagnetic-compatibility (EMC) testing standards have added an impulse RF spike of either 5 or 100 kHz. This impulse is used to emulate the effects of a high-powered base-station communications amplifier or a ground-based-radar antenna burst. In order to improve repeatability, increase dynamic range, and more accurately measure pulse power, an engineer may consider using a peak power sensor in place of a traditional diode detector. Bob Muro of Boonton, a Wireless Telecom Group company, provides insight into this topic in the four-page whitepaper, “Using RF Power Meters for EMC Testing.”

As an electrical science, EMC studies the susceptibility of electronic devices to compromised operation in response to EMI signals. A device is considered to have achieved EMC when its design addresses both the emission and susceptibility aspects of its operation. Immunity testing is critical for a variety of electrical systems that could be negatively impacted by significant radiation, such as the CANBUS system for intercommunication of vehicular subsystems. In an EMI/EMC test, a radiative source generates an RF impulse and the victim device is subjected to the radiation while operating. This testing is often done in an anechoic test chamber to avoid misreading the measurements caused by reflections.

The single-step closed-loop method or two-step substitution method are commonly used for such testing. The closed-loop method has the detector and device-under-test (DUT) in the same test chamber. The substitution method uses the detector as a calibration of the radiative source prior to testing the DUT. For both methods, a peak power sensor that can correctly calculate the power values of a signal (when it is either pulsed or under modulation) would provide a more dynamic and accurate measurement of power levels. This improvement over a diode detector could give engineers a better understanding of a device’s EMC while showing whether it complies with the necessary standards.

Boonton, 25 Eastmans Rd., Parsippany, NJ 07054; (973) 386-9696.

Download this article in .PDF format
This file type includes high resolution graphics and schematics when applicable.

Sponsored Recommendations

UHF to mmWave Cavity Filter Solutions

April 12, 2024
Cavity filters achieve much higher Q, steeper rejection skirts, and higher power handling than other filter technologies, such as ceramic resonator filters, and are utilized where...

Wideband MMIC Variable Gain Amplifier

April 12, 2024
The PVGA-273+ low noise, variable gain MMIC amplifier features an NF of 2.6 dB, 13.9 dB gain, +15 dBm P1dB, and +29 dBm OIP3. This VGA affords a gain control range of 30 dB with...

Fast-Switching GaAs Switches Are a High-Performance, Low-Cost Alternative to SOI

April 12, 2024
While many MMIC switch designs have gravitated toward Silicon-on-Insulator (SOI) technology due to its ability to achieve fast switching, high power handling and wide bandwidths...

Request a free Micro 3D Printed sample part

April 11, 2024
The best way to understand the part quality we can achieve is by seeing it first-hand. Request a free 3D printed high-precision sample part.