High performance RF/microwave equipment is extremely expensive and sensitive. Special care must be taken to avoid test equipment damage.

How Not to Break your Network Analyzer

May 14, 2015
Proper technique can ensure that a highly sensitive and expensive instrument is put to use making quality measurements instead of sitting on a repair bench.

Network analyzers are one of the core instruments used in RF/microwave device development, characterization, and verification. As these instruments are necessarily very sensitive machines, they are prone to mechanical and electrical damage if improperly handled. In an application note by Keysight Technologies, tips for avoiding long repair cycles or costly equipment replacement requisitions are suggested.

Ensuring proper electrical power and grounding is essential for network analyzer operation. If the machine is improperly grounded, charge could build, injuring the user or damaging machine. The note reminds that these instruments tend to be supplied with a variety of warning labels and instructions in the datasheets and manuals in order to prevent mishaps.

The ports of a network analyzer are also sensitive to electrical and RF power at the inputs. Having an understanding of the range of power the ports can handle will aid in preventing overpowering and damaging the internal measurement circuitry. Ensuring that during power cycles the instrument ports only experience the minimum safety level will also prevent startup or shutdown voltage swells or sags. The note points out that DC blocks, limiters, or external attenuators may be necessary in certain testing scenarios to avoid instrument damage.

Mechanically speaking, the RF port connectors are precision parts that can easily be damaged at the connection to the instrument body or internally. To ensure RF connector safety, proper cable handling, inspection, cleaning, and electrostatic discharge (ESD) protections are valuable. ESD is an especially important consideration when packing the equipment for relocation or shipping, as they could come into contact with electric fields outside of a protected facility.

Especially during operation, adequate ventilation in a low humidity environment will not only prevent catastrophic failure, but also increase equipment lifetime. As higher performance network analyzers are often rather large and heavy pieces of equipment full of electronic components, proper physical transport is also critical. The vibrations and jarring that regularly occur during transporting packages can easily damage a network analyzer. Therefore, proper packing materials are necessary. Finally, the note indicates that styrene pellets should never be used due to static generation and inadequate device protection.

Keysight Technologies, 1400 Fountaingrove Pkwy., Santa Rosa, CA 95403, (707) 577-5030

Sponsored Recommendations

UHF to mmWave Cavity Filter Solutions

April 12, 2024
Cavity filters achieve much higher Q, steeper rejection skirts, and higher power handling than other filter technologies, such as ceramic resonator filters, and are utilized where...

Wideband MMIC Variable Gain Amplifier

April 12, 2024
The PVGA-273+ low noise, variable gain MMIC amplifier features an NF of 2.6 dB, 13.9 dB gain, +15 dBm P1dB, and +29 dBm OIP3. This VGA affords a gain control range of 30 dB with...

Fast-Switching GaAs Switches Are a High-Performance, Low-Cost Alternative to SOI

April 12, 2024
While many MMIC switch designs have gravitated toward Silicon-on-Insulator (SOI) technology due to its ability to achieve fast switching, high power handling and wide bandwidths...

Request a free Micro 3D Printed sample part

April 11, 2024
The best way to understand the part quality we can achieve is by seeing it first-hand. Request a free 3D printed high-precision sample part.