[Test & Measurement] Three-Probe Tuner Tackles Multiple Tasks This combination of software and a versatile three-probe tuner system provides true broadband prematching, harmonic, and zero-vibration tuning without a change in hardware. Cristos Tsironis | ED Online ID #9793 | February 2005 Electromechanical impedance tuners provide the appealing combination of extremely high VSWR (to 200:1) and high power-handling capability (to 400 W CW). Until now, electromechanical slide screw tuners have been built as wideband models (with two probes of different lengths), as high-VSWR systems (with a prematching stage), or as harmonic rejection tuners, although not with all three characteristics at the same time. The MPT Multi-Purpose Tuners from Focus Microwaves (Montreal, Quebec, Canada) change all that by combining multioctave tuning, high VSWR, stable performance with wide-instantaneous-bandwidth harmonic load-pull capability from a single, compact system. Electromechanical tuners provide excellent resolution, with several million tunable points at any frequency. Interpolated tuning allows adjustment to almost any impedance over a wide range, with almost ideal lowpass behavior (because they use a 50-Ω transmission airline as default media) and comprehensive harmonic tuning using harmonic rejection tuners or frequency discriminators (triplexers).1 Wideband tuners can pose a problem when used for load-pull testing of highly compressed transistors without separate harmonic tuning. The effect of uncontrollably dangling harmonic impedances generates nonquantifiable and noncorrectable systematic measurement errors, which falsify the basic form of the load-pull contours.2 To avoid such errors, complex harmonic load-pull setups have been using, some with frequency triplexers and a trio of tuners3 and some with one wideband and one harmonic-rejection tuner per device under test (DUT).4 The MPT is an important evolution of the slide-screw electromechanical tuner, with three cascaded and independent wideband probes. The patent-pending MPT can be used as a harmonic tuner (covering the fundamental, second-harmonic, and third-harmonic frequencies) over the full bandwidth of the probes, as a high-VSWR prematching tuner, as an ultrawideband tuner for continuous frequency coverage, and as an ultrastable tuner for on-wafer applications. One example of the MPT series is the model MPT 1840, with frequency coverage from 4 to 18 GHz (Fig. 1). Slide-screw tuners create a variable reflection factor by means of a metallic probe, capacitively coupled to the center conductor of a slotted airline (slabline). The amplitude of the reflection factor is increased by inserting the probe into the slotted airline (Fig. 2). By moving the probe horizontally, the phase is adjusted. A movement of one-half wavelength at a given frequency along the slabline accounts for 360 deg. control of phase. As a result, any impedance up to the maximum tuning range (VSWRmax) of the tuner can be created. Typical values of VSWRmax vary between 12.0:1 and 30.0:1 for single-probe tuners (Γ = 0.846 to 0.935). Dual-probe tuners, if configured properly (prematching) may create VSWRs to 200.0:1 (Γ = 0.99) at C-band frequencies. Arbitrary reflection factors can also be generated by using three variable stubs at a fixed distance to each other (mechanical variable stub tuner),5 or an array of PIN diodes that can be switched on and off electrically.6 These approaches are optimum when the electrical distance between individual reflection factors is 120 deg. Assuming each one of three independent probes (slugs) P1, P2, P3 are positioned 120 deg. from each-other and their amplitudes (vertical positions) are changed independently, every point on the Smith Chart can be attained as a vector combination of two reflection factors at a time (P3a + P2b= A and P1=0). Of course, that optimum spacing of 120 deg. is only valid for a single frequency, limiting coverage on the Smith Chart for other frequencies. Also, the shorted stubs of traditional multistub tuners act either as capacitors or inductors, depending on the frequency, and thus change the basic tuning behavior. The MPT approach allows free positioning of each probe horizontally and thus selecting the optimum phase between probes at every frequency. MPT tuners can be manufactured using existing technology. The system calls for a minimum of three independent carriages and probes (slugs), but uses the same design as used in traditional slide-screw tuners. The MPT systems do require three independent horizontal drives, since the company's tuners are based on a lead screw centered on each mobile carriage. But using three smaller-than-normal axes centered in the carriage has made this possible. The MPT tuners are calibrated using a precalibrated commercial vector network analyzer (VNA). VNA calibration must be carried out previously, using through-reflect-line (TRL) calibration techniques and meticulous verification. MPT calibration can be performed in situ (with) or by connecting the MPT tuner directly to the VNA. In situ calibration performs measurements on other test-related components remaining connected to the measurement setup, and then dembeds the electrical contributions of these additional components from the S-parameter measurements through specialized algorithms. In-situ techniques are more delicate to execute, but provide better accuracy due to fewer disconnections; they are recommended for measurements above 10 GHz. The MPT has three independent cascaded tuning sections. The total combined calibration points, if each section were calibrated at 455 points, is (455)3 = 94,196,375 per harmonic frequency. Because of the difficulty in calibrating so many points even with fast computers and VNAs, the Focus MPT software incorporates a calibration algorithm which generates all 94 million possible combinations of points per set of fundamental and harmonic frequencies in less than 30 minutes. With second-order interpolation, even more impedance states can be synthesized, limited only by the mechanical resolution of the stepper motors and translation gears. A full MPT calibration, including calibration points for three tuning sections and a set of harmonic frequencies (f0, 2f0, and 3f0) is saved in a tuner calibration file (typically only 60 to 120 kB). The calibration data are retrieved in memory during the operation and impedances for each harmonic frequency can be synthesized by using one of the possible combinations of the large number of tuner positions. MPT reflection factors are created either by a single probe or by combining two or three individual reflection vectors (Fig. 3). After the MPT has been calibrated it can be used either as a
Vibration-free operation can be achieved by eliminating horizontal tuner movement. In this approach, the horizontal distance between the three probes is fixed (typically 120 deg. apart) and calibration points are distributed by means of vertical probe movement only [Figs. 4(a)and 4(b)]. Of course, if both horizontal and vertical movements are used for all three probes, then several million impedance states are available for f0, 2f0, and 3f0 frequencies.
| |||||||||||||||||||||||||||||||||||||||||||||||||
Resources

RSS














